Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Animals (Basel) ; 12(7)2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35405837

RESUMO

Computer-vision systems for herd detection and monitoring are increasingly present in precision livestock. This technology provides insights into how environmental variations affect the group's movement pattern. We hypothesize that the cluster and unrest indexes based on computer vision (CV) can simultaneously assess the movement variation of reared broilers under different environmental conditions. The present study is a proof of principle and was carried out with twenty broilers (commercial strain Cobb®), housed in a controlled-environment chamber. The birds were divided into two groups, one housed in an enriched environment and the control. Both groups were subjected to thermal comfort conditions and heat stress. Image analysis of individual or group behavior is the basis for generating animal-monitoring indexes, capable of creating real-time alert systems, predicting welfare, health, environment, and production status. The results obtained in the experiment in a controlled environment allowed the validation of the simultaneous application of cluster and unrest indexes by monitoring the movement of the group of broilers under different environmental conditions. Observational results also suggest that research in more significant proportions should be carried out to evaluate the potential positive impact of environmental enrichment in poultry production. The complexity of the environment is a factor to be considered in creating alert systems for detecting heat stress in broiler production. In large groups, birds' movement and grouping patterns may differ; therefore, the CV system and indices will need to be recalibrated.

2.
An Acad Bras Cienc ; 93(2): e20191048, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34259795

RESUMO

The present study aimed to evaluate the use of organic and inorganic minerals in Cobb500 broiler breeder diet and its effects on the performance. The birds were housed in an experimental house at Poultry Laboratory of the Federal University of Santa Maria with 20 floor pens of 4.61m2 each. The experiment was conducted between 51st and 65th weeks of age of birds. The design was completely randomized with four treatments and five pen replicates with 22 hens and 2 roosters each. The treatments evaluated were: PI=100% mineral inorganic premix; PO= 100% mineral organic premix: PI+PO= 70% mineral inorganic premix + 30% mineral organic premix and PI+Zn= 100% mineral inorganic premix, except zinc mineral, that was 70% inorganic form and 30% organic form. The following parameters of performance and egg quality were evaluated: laying rate, body weight, egg, albumen and yolk weight, yolk color and specific gravity of eggs. These parameters were performed one day per week throughout the experimental period to evaluated egg quality. Under the conditions and time that the experiment was conducted, the use of organic minerals had no significant effect on the performance and egg quality parameters evaluated in the broiler breeders.


Assuntos
Ração Animal , Galinhas , Ração Animal/análise , Animais , Dieta , Suplementos Nutricionais , Feminino , Masculino , Minerais
3.
Ciênc. rural (Online) ; 51(8): e20200941, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1278899

RESUMO

ABSTRACT: This study evaluated: (1) the vulnerability of broiler houses with different cooling systems, and (2) the spatial distribution of environmental variables during hot days. Four potentially vulnerable commercial broiler houses in southern Brazil were selected according to the following parameters: absence or presence of different cooling systems, broilers older than 28 days, and outside air dry-bulb temperature over 30°C. Broiler house vulnerability was classified according to the cooling and mechanical ventilation system: cellulose pad cooling (CPC), sprinkling (SPK), fogging (FOG), and mechanical ventilation without evaporative cooling system (VTL). The air dry-bulb temperature (Tdb, °C) and relative humidity (RH, %) were recorded every 10 min. For each broiler house, we evaluated: (1) relative cooling efficiency (RCE) and (2) inside spatial distribution of microclimate variables using a geostatistical technique. The CPC and SPK did not differ (P<0.05) in RCE (81.6% and 80.7%, respectively), but both differed from FOG (23.8%) and VLT (1.87%) systems. The highest variations in indoor Tdb were recorded in the FOG (7 °C), followed by the SPK (4 °C) and CPC (3 °C). In the CPC, there was an increase in RH from the middle to the end of the broiler house near the exhaust fans. In conclusion, the relative cooling efficiency and the inside spatial distributions of environmental variables in the broiler houses were influenced by the existing cooling system.


RESUMO: Os objetivos deste estudo foram (1) comparar a vulnerabilidade de aviários com diferentes sistemas de resfriamento, e (2) avaliar a distribuição espacial interna das variáveis ambientais durante dias quentes. Quatro aviários comerciais potencialmente vulneráveis no sul do Brasil foram selecionados de acordo com os seguintes parâmetros de elegibilidade: ausência ou presença de diferentes sistemas de resfriamento; frangos de corte com mais de 28 dias de idade; e temperatura de bulbo seco do ar externa acima de 30 °C. A vulnerabilidade do aviário foi classificada de acordo com o sistema de resfriamento e ventilação mecânica, sendo: resfriamento por pad cooling (CPC), aspersão (SPK), nebulização (FOG) e ventilação mecânica sem sistema de resfriamento evaporativo (VTL). A temperatura de bulbo seco do ar (Tbs, °C) e a umidade relativa do ar (UR, %) foram coletadas por registradores de dados autônomos a cada 10 min. Para cada aviário foram avaliados: (1) eficiência relativa de resfriamento (RCE) e (2) distribuição espacial interna das variáveis ambientais por técnica de geoestatística. O CPC e SPK não diferiram (P>0,05) na RCE (81,6% e 80,7% respectivamente), mas ambos diferiram do FOG (23,8%) e VLT (1,87%). As maiores variações na Tbs do ar interno foram registradas no FOG (7 °C), seguido pelo SPK (4 °C) e CPC (3 °C). No CPC, houve um aumento da umidade relativa do meio para o final do aviário, próximo aos exaustores. Em conclusão, a eficiência relativa de resfriamento, assim como a distribuição espacial das variáveis ambientais internas foram influenciadas pelo sistema de resfriamento de cada aviário.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA